Seismic evaluation of earthquake resistance and retrofitting measures for two story masonry houses

Abstract

This paper discusses on the shaking table test results of two 1:4 scale model of two-storymasonry structure typically used in constructing low-rise residential buildings. This test is performed to provide a better understanding of the seismic behavior of the PP-band (polypropylene band) mesh retrofitted adobe masonry house. The test structure is subjected to a series of different levels of harmonicmotion that applied along the longitudinal direction. The results of the shaking table tests on building models show that the PP-band retrofitting technique can enhance the safety of masonry buildings, even during severe ground motion.

Description

Citation

Sathiparan, N., Sakurai, K., Numada, M., & Meguro, K. (2014). Seismic evaluation of earthquake resistance and retrofitting measures for two story masonry houses. Bulletin of earthquake engineering, 12(4), 1805-1826.

Endorsement