Study on seismic performance Of low earthquake resistant masonry buildings Retrofitted by pp-band mesh

dc.contributor.authorSathiparan, N.
dc.contributor.authorMeguro, K.
dc.date.accessioned2021-03-02T08:20:40Z
dc.date.accessioned2022-06-27T09:47:16Z
dc.date.available2021-03-02T08:20:40Z
dc.date.available2022-06-27T09:47:16Z
dc.date.issued2010
dc.description.abstractThis paper introduces a technically feasible and economically affordable PP-band (polypropylene bands) retrofitting for low earthquake resistant masonry structures in developing countries. Results of shaking table tests on building models show that the PP-band retrofitting technique can enhance safety of both existing and new masonry buildings even in worst case scenario of earthquake ground motion like JMA7 seismic intensity. Therefore proposed method can be one of the optimum solutions for promoting safer building construction in developing countries and contribute earthquake disaster mitigation in future.en_US
dc.identifier.urihttp://repo.lib.jfn.ac.lk/ujrr/handle/123456789/1741
dc.language.isoenen_US
dc.subjectUnreinforced masonryen_US
dc.subjectPolypropylene banden_US
dc.titleStudy on seismic performance Of low earthquake resistant masonry buildings Retrofitted by pp-band meshen_US